Parameter

Description

LOADTM

Type: EC Parameter

Description: Time in seconds prior to vessel loading when ASC Optimizer considers a container for transfer zone (TZ) buffering. To prevent congestion in the waterside TZ, ASC Optimizer does not move a soon-to-be-loaded container to a waterside TZ before this time. Crane schedule and load queue both define the reference time.

Default: 1800

Module: Equipment Control with ECN4

Area/Option: AYC Manager Option

OPTSCH

Type: EC Parameter

Description: Determines if the ASC Optimizer considers preposition moves as part of normal calculations. When set to 1 (true), preposition moves are considered. When set to 0 (false), only inbound and outbound moves are considered, and preposition moves are not. For more information, see JPROPP and JPROWO parameters.

Default: 0

Module: Equipment Control with ECN4

Area/Option: AYC Manager Option