Parameter |
Description |
---|---|
LOADTM |
Type: EC Parameter Description: Time in seconds prior to vessel loading when ASC Optimizer considers a container for transfer zone (TZ) buffering. To prevent congestion in the waterside TZ, ASC Optimizer does not move a soon-to-be-loaded container to a waterside TZ before this time. Crane schedule and load queue both define the reference time. Default: 1800 Module: Equipment Control with ECN4 Area/Option: AYC Manager Option |
OPTSCH |
Type: EC Parameter Description: Determines if the ASC Optimizer considers preposition moves as part of normal calculations. When set to 1 (true), preposition moves are considered. When set to 0 (false), only inbound and outbound moves are considered, and preposition moves are not. For more information, see JPROPP and JPROWO parameters. Default: 0 Module: Equipment Control with ECN4 Area/Option: AYC Manager Option |